Sometimes You can get ” RMAN-03008: error while performing automatic resync of recovery catalog ” error.

 

Details of error are as follows.

RMAN-03008: error while performing automatic resync of recovery catalog
Cause: This message should be accompanied by other error message(s) indicating the cause of the error.
Action: Check the accompanying errors.
RMAN> register database;
starting full resync of recovery catalog
full resync complete
database registered in recovery catalog
RMAN-00571: ===========================================================
RMAN-00569: =============== ERROR MESSAGE STACK FOLLOWS ===============
RMAN-00571: ===========================================================
RMAN-03008: error while performing automatic resync of recovery catalog
RMAN-20020: database incarnation not set



When you connect to RMAN Catalog database and You can get the following error during the register database,

rman
connect catalog user/pwd@CATALOG_DB
connect target /
RMAN> register database;
starting full resync of recovery catalog
full resync complete
database registered in recovery catalog
RMAN-00571: ===========================================================
RMAN-00569: =============== ERROR MESSAGE STACK FOLLOWS ===============
RMAN-00571: ===========================================================
RMAN-03008: error while performing automatic resync of recovery catalog
RMAN-20020: database incarnation not set

 

To solve this error, connect catalog database and run the unregister and register database again.

connect catalog user/pwd@CATALOG_DB
connect target /

RMAN> unregister database;
RMAN> register database;

 

 

 

Do you want to learn more details about RMAN, then read the following articles.